Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 68(5)2023 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-36780697

RESUMO

Dosimetric calculations, whether for radiation protection or nuclear medicine applications, are greatly influenced by the use of computational models of humans, called anthropomorphic phantoms. As anatomical models of phantoms have evolved and expanded, thus has the need for quantifying differences among each of these representations that yield variations in organ dose coefficients, whether from external radiation sources or internal emitters. This work represents an extension of previous efforts to quantify the differences in organ positioning within the body between a stylized and voxel phantom series. Where prior work focused on the organ depth distribution vis-à-vis the surface of the phantom models, the work described here quantifies the intra-organ and inter-organ distributions through calculation of the mean chord lengths. The revised Oak Ridge National Laboratory stylized phantom series and the University of Florida/National Cancer Institute voxel phantom series including a newborn, 1-, 5-, 10- and 15 year old, and adult phantoms were compared. Organ distances in the stylized phantoms were computed using a ray-tracing technique available through Monte Carlo radiation transport simulations in MCNP6. Organ distances in the voxel phantom were found using phantom matrix manipulation. Quantification of differences in organ chord lengths between the phantom series displayed that the organs of the stylized phantom series are typically situated farther away from one another than within the voxel phantom series. The impact of this work was to characterize the intra-organ and inter-organ distributions to explain the variations in updated internal dose coefficient quantities (i.e. specific absorbed fractions) while providing relevant data defining the spatial and volumetric organ distributions in the phantoms for use in subsequent internal dosimetric computations, with prospective relevance to patient-specific individualized dosimetry, as well as informing machine learning definition of organs using these reference models.


Assuntos
Proteção Radiológica , Radiometria , Recém-Nascido , Adulto , Humanos , Criança , Adolescente , Estudos Prospectivos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador , Imagens de Fantasmas , Método de Monte Carlo , Doses de Radiação
2.
Health Phys ; 119(2): 163-175, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31913861

RESUMO

In the event of a radiological incident, the release of fission products into the surrounding environment and the ensuing external contamination present a challenge for triage assessment by emergency response personnel. Reference exposure rate and skin dose rate calibration data for emergency response personnel are currently lacking for cases where receptors are externally contaminated with fission products. Simulations were conducted to compute reference exposure rate coefficients and skin dose rate coefficients from photon-emitting fission products of radiological concern. To accomplish this task, simplified mathematical skin phantoms were created using surface area and height specifications from International Commission on Radiological Protection Publication 89. Simulations were conducted using Monte Carlo radiation transport code using newborn, 1-y-old, 5-y-old, 10-y-old, 15-y-old, and adult phantoms for 22 photon-emitting radionuclides. Exposure rate coefficient data were employed in a case study simulating the radionuclide inventory for a 17 × 17 Westinghouse pressurized water reactor, following three burn-up cycles at 14,600 MWd per metric ton of uranium. The decay times following the final cycle represent the relative activity fractions over a period of 0.5-30 d. The resulting data can be used as calibration standards for triage efforts in emergency response protocols.


Assuntos
Exposição à Radiação/prevenção & controle , Proteção Radiológica/métodos , Adolescente , Adulto , Calibragem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Cinética , Masculino , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Doses de Radiação , Proteção Radiológica/estatística & dados numéricos , Liberação Nociva de Radioativos , Medição de Risco , Pele
4.
Radiat Environ Biophys ; 56(4): 453-462, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28840329

RESUMO

External dose coefficients for environmental exposure scenarios are often computed using assumption on infinite or semi-infinite radiation sources. For example, in the case of a person standing on contaminated ground, the source is assumed to be distributed at a given depth (or between various depths) and extending outwards to an essentially infinite distance. In the case of exposure to contaminated air, the person is modeled as standing within a cloud of infinite, or semi-infinite, source distribution. However, these scenarios do not mimic common workplace environments where scatter off walls and ceilings may significantly alter the energy spectrum and dose coefficients. In this paper, dose rate coefficients were calculated using the International Commission on Radiological Protection (ICRP) reference voxel phantoms positioned in rooms of three sizes representing an office, laboratory, and warehouse. For each room size calculations using the reference phantoms were performed for photons, electrons, and positrons as the source particles to derive mono-energetic dose rate coefficients. Since the voxel phantoms lack the resolution to perform dose calculations at the sensitive depth for the skin, a mathematical phantom was developed and calculations were performed in each room size with the three source particle types. Coefficients for the noble gas radionuclides of ICRP Publication 107 (e.g., Ne, Ar, Kr, Xe, and Rn) were generated by folding the corresponding photon, electron, and positron emissions over the mono-energetic dose rate coefficients. Results indicate that the smaller room sizes have a significant impact on the dose rate per unit air concentration compared to the semi-infinite cloud case. For example, for Kr-85 the warehouse dose rate coefficient is 7% higher than the office dose rate coefficient while it is 71% higher for Xe-133.


Assuntos
Exposição Ocupacional/análise , Doses de Radiação , Humanos , Imersão , Masculino , Exposição Ocupacional/normas , Imagens de Fantasmas , Padrões de Referência , Pele/efeitos da radiação
5.
Radiat Environ Biophys ; 56(3): 255-267, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28493137

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge has undertaken calculations related to various environmental exposure scenarios. A previous paper reported the results for submersion in radioactive air and immersion in water using age-specific mathematical phantoms. This paper presents age-specific effective dose rate coefficients derived using stylized mathematical phantoms for exposure to contaminated soils. Dose rate coefficients for photon, electron, and positrons of discrete energies were calculated and folded with emissions of 1252 radionuclides addressed in ICRP Publication 107 to determine equivalent and effective dose rate coefficients. The MCNP6 radiation transport code was used for organ dose rate calculations for photons and the contribution of electrons to skin dose rate was derived using point-kernels. Bremsstrahlung and annihilation photons of positron emission were evaluated as discrete photons. The coefficients calculated in this work compare favorably to those reported in the US Federal Guidance Report 12 as well as by other authors who employed voxel phantoms for similar exposure scenarios.


Assuntos
Imagens de Fantasmas , Exposição à Radiação/análise , Radiometria/instrumentação , Poluentes Radioativos do Solo/análise , Adolescente , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido
6.
Radiat Prot Dosimetry ; 174(2): 275-286, 2017 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-27150517

RESUMO

The Oak Ridge National Laboratory Center for Radiation Protection Knowledge (CRPK) has undertaken a number of calculations in support of a revision to the United States Environmental Protection Agency (US EPA) Federal Guidance Report on external exposure to radionuclides in air, water and soil (FGR 12). Age-specific mathematical phantom calculations were performed for the conditions of submersion in radioactive air and immersion in water. Dose rate coefficients were calculated for discrete photon and electron energies and folded with emissions from 1252 radionuclides using ICRP Publication 107 decay data to determine equivalent and effective dose rate coefficients. The coefficients calculated in this work compare favorably to those reported in FGR12 as well as by other authors that employed voxel phantoms for similar exposure scenarios.


Assuntos
Proteção Radiológica , Poluentes Radioativos , Ar , Humanos , Imagens de Fantasmas , Fótons , Doses de Radiação , Monitoramento de Radiação , Radioisótopos , Estados Unidos , Água
7.
Radiat Prot Dosimetry ; 172(4): 367-374, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26838066

RESUMO

As part of a broader effort to calculate effective dose rate coefficients for external exposure to photons and electrons emitted by radionuclides distributed in air, soil or water, age-specific stylized phantoms have been employed to determine dose coefficients relating dose rate to organs and tissues in the body. In this article, dose rate coefficients computed using the International Commission on Radiological Protection reference adult male voxel phantom are compared with values computed using the Oak Ridge National Laboratory adult male stylized phantom in an air submersion exposure geometry. Monte Carlo calculations for both phantoms were performed for monoenergetic source photons in the range of 30 keV to 5 MeV. These calculations largely result in differences under 10 % for photon energies above 50 keV, and it can be expected that both models show comparable results for the environmental sources of radionuclides.


Assuntos
Modelos Teóricos , Neoplasias/radioterapia , Imagens de Fantasmas , Fótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Ar , Algoritmos , Carga Corporal (Radioterapia) , Elétrons , Humanos , Masculino , Método de Monte Carlo , Órgãos em Risco , Proteção Radiológica , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...